TY - JOUR KW - Humans KW - Animals KW - Aqueous Humor KW - DNA, Protozoan KW - Eye Infections, Parasitic KW - Real-Time Polymerase Chain Reaction KW - Toxoplasma KW - Toxoplasmosis, Ocular KW - Uveitis, Posterior AU - Carlos Gomez AU - Malaya Sahoo AU - Ghazala Kahn AU - Lina Zhong AU - José Montoya AU - Benjamin Pinsky AU - Thuy Doan AB -

BACKGROUND: is the most common infectious cause of posterior uveitis worldwide. Two multicopy targets (B1 and Rep529) are commonly used in PCR assays, but studies evaluating these targets in ocular fluid samples are limited. Herein, we determine the analytical characteristics of a single-reaction, internally controlled, dual-target, real-time PCR and evaluate the clinical performance of this assay in intraocular fluid samples obtained at a reference ophthalmologic centre in the USA.

METHODS: Lower limits of detection for the B1 and Rep529 components of the dual-target assay were determined using serial dilutions of cultured strain Z185. The dual-target assay was then used to test 148 archived intraocular samples (132 vitreous,16 aqueous humour) collected at the Francis I. Proctor Foundation between January 2010 and December 2015 for testing by a nested, conventional PCR targeting the B1 gene.

RESULTS: The 95% lower limits of detection for the dual-target assay was determined to be 1.05 tachyzoites/mL for B1 and 0.83 tachyzoites/mL for Rep529. Using archived clinical intraocular specimens, the dual-target assay demonstrated 97.2% positive per cent agreement (n=35/36; 95% CI 83.7% to 99.9%) and 99.1% negative per cent agreement (n=111/112; 95% CI 94.4% to 100%) compared with the nested, conventional B1 PCR.

CONCLUSION: This single-reaction, internally controlled, dual-target (B1, Rep529) real-time PCR for the detection of DNA in intraocular specimens demonstrated excellent agreement with nested, conventional, B1 PCR. The dual-target design may ensure detection when variation is present in one of two target regions.

BT - Br J Ophthalmol DA - 2019 04 DO - 10.1136/bjophthalmol-2018-313064 IS - 4 J2 - Br J Ophthalmol LA - eng N2 -

BACKGROUND: is the most common infectious cause of posterior uveitis worldwide. Two multicopy targets (B1 and Rep529) are commonly used in PCR assays, but studies evaluating these targets in ocular fluid samples are limited. Herein, we determine the analytical characteristics of a single-reaction, internally controlled, dual-target, real-time PCR and evaluate the clinical performance of this assay in intraocular fluid samples obtained at a reference ophthalmologic centre in the USA.

METHODS: Lower limits of detection for the B1 and Rep529 components of the dual-target assay were determined using serial dilutions of cultured strain Z185. The dual-target assay was then used to test 148 archived intraocular samples (132 vitreous,16 aqueous humour) collected at the Francis I. Proctor Foundation between January 2010 and December 2015 for testing by a nested, conventional PCR targeting the B1 gene.

RESULTS: The 95% lower limits of detection for the dual-target assay was determined to be 1.05 tachyzoites/mL for B1 and 0.83 tachyzoites/mL for Rep529. Using archived clinical intraocular specimens, the dual-target assay demonstrated 97.2% positive per cent agreement (n=35/36; 95% CI 83.7% to 99.9%) and 99.1% negative per cent agreement (n=111/112; 95% CI 94.4% to 100%) compared with the nested, conventional B1 PCR.

CONCLUSION: This single-reaction, internally controlled, dual-target (B1, Rep529) real-time PCR for the detection of DNA in intraocular specimens demonstrated excellent agreement with nested, conventional, B1 PCR. The dual-target design may ensure detection when variation is present in one of two target regions.

PY - 2019 SP - 569 EP - 572 T2 - Br J Ophthalmol TI - Dual-target, real-time PCR for the diagnosis of intraocular infections. VL - 103 SN - 1468-2079 ER -